DMSTA Simulation Results Case: Cell-4 Period: 02/01/95 to 09/30/01
Case: ENRP Cell 4 (SAV) - Depths Forced - Calibrated thru Sept 2000
Input Series Cell4_f Tanks in Series 2.1 Surface Area (km2) 1.4700
Simulation Period 02/01/95 thru 09/30/01 Mean Water Load  (cm/d) 13.7 Bypass Volume 0.0%
Output Period 02/01/95 thru 09/30/01 Max Water Load (cm/d) 61.2 Mean Depth (cm) 65
Startup Interval (days) 486 Iterations 1 Inflow Conc  (ppb) 47.6 Max Depth (cm) 119
Avg Interval (days) 7 Inflow P Load (mg/m2-yr) 2477 Freq Depth <  5 cm 0.0%
Parameter Set:   none Outflow FWM  Conc (ppb) 19.1 Load Reduction 62%
K  (m/yr) 71.94 Sm (mg/m2)  0 Outflow C with Bypass 19.1 Time Freq Conc > 10 ppb 93%
C1 (ppb) 22.0 Sp (mg/m2) 0 95th Percentile (ppb) 28.1 Vol Freq Conc > 10 ppb 98%
C0  (ppb) 4.0 Qout Intercept 0.0 Outflow Geo. Mean (ppb) 17.3 Storage Turnover (1/yr) 8.7
Zx  (cm) 60 Qout Exponent 0.0 Outflow GM,  Q>0 (ppb) 17.3 Mean Stored P (mg/m2) 1000
Wtr Bal Error 0.0% Knet-Plug Flow (m/yr) 45.5 Storage Inc/Net Removal 9%
Mass B Error 0.1% Knet-NCSTR (m/yr) 57.3 Outfl. Seepage (cm/d/cm) 0.008
Calibration  Statistics for Period: 06/01/96 thru 10/01/00 Mean Mean
Count Observed Predicted Residual Resid% RSE% R2
Mean Depth (cm) 226 66.4 66.3 0.0 0% 1% 100%
Flow (cm/day) 226 12.53 13.03 -0.50 -4% 15% 93%
Flow-Wtd-Mean Conc (ppb) 224 20.7 19.8 0.9 5%
Geometric Mean Conc (ppb) 224 17.8 17.8 0.0 0% 36% 38%
Mean Conc (ppb) 224 19.9 18.6 1.3 7% 46% 29%
Outflow Load (mg/m2-d) 226 2.59 2.57 0.01 1% 57% 59%
Pred Q x Conc (mg/m2-d) 224 2.72 2.60 0.12 5% 51% 61%
 
 
Obs Load2 = Predicted Flow x Obs Conc
Green lines on x axis of concentration plots indicate model calibration period.
06/07/02